Liquid-metal-based three-dimensional microelectrode arrays integrated with implantable ultrathin retinal prosthesis for vision restoration

Full metadata record
DC Field Value Language
dc.contributor.author정원기-
dc.contributor.authorJang Jiuk-
dc.contributor.authorCui Gang-
dc.contributor.authorLee Sanghoon-
dc.contributor.authorJeong Han-
dc.contributor.authorKang Haisu-
dc.contributor.authorSeo Hunkyu-
dc.contributor.authorKim Sumin-
dc.contributor.authorKim Enji-
dc.contributor.authorLee Junwon-
dc.contributor.authorLee Seung Geol-
dc.contributor.authorByeon Suk Ho-
dc.contributor.authorPark Jang-Ung-
dc.date.accessioned2024-09-30T07:00:16Z-
dc.date.available2024-09-30T07:00:16Z-
dc.date.issued2024-05-
dc.identifier.issn1748-3387-
dc.identifier.issn1748-3395-
dc.identifier.urihttps://yscholarhub.yonsei.ac.kr/handle/2021.sw.yonsei/23068-
dc.description.abstractElectronic retinal prostheses for stimulating retinal neurons are promising for vision restoration. However, the rigid electrodes of conventional retinal implants can inflict damage on the soft retina tissue. They also have limited selectivity due to their poor proximity to target cells in the degenerative retina. Here we present a soft artificial retina (thickness, 10 mu m) where flexible ultrathin photosensitive transistors are integrated with three-dimensional stimulation electrodes of eutectic gallium-indium alloy. Platinum nanoclusters locally coated only on the tip of these three-dimensional liquid-metal electrodes show advantages in reducing the impedance of the stimulation electrodes. These microelectrodes can enhance the proximity to the target retinal ganglion cells and provide effective charge injections (72.84 mC cm-2) to elicit neural responses in the retina. Their low Young's modulus (234 kPa), owing to their liquid form, can minimize damage to the retina. Furthermore, we used an unsupervised machine learning approach to effectively identify the evoked spikes to grade neural activities within the retinal ganglion cells. Results from in vivo experiments on a retinal degeneration mouse model reveal that the spatiotemporal distribution of neural responses on their retina can be mapped under selective localized illumination areas of light, suggesting the restoration of their vision.,A soft artificial retina with flexible phototransistors and three-dimensional liquid-metal microelectrodes is used to enhance proximity to retinal ganglion cells and minimize damage to soft tissue as well as improve charge injection for vision restoration in retinal degenerative in vivo models.,-
dc.language영어-
dc.language.isoENG-
dc.publisherNature Publishing Group-
dc.titleLiquid-metal-based three-dimensional microelectrode arrays integrated with implantable ultrathin retinal prosthesis for vision restoration-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1038/s41565-023-01587-w-
dc.identifier.wosid001142543100003-
dc.identifier.bibliographicCitationNature Nanotechnology, v.19, no.5-
dc.citation.titleNature Nanotechnology-
dc.citation.volume19-
dc.citation.number5-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > 공과대학 신소재공학부 > 공과대학 신소재공학과 > 1. Journal Articles

qrcode

Items in Scholar Hub are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Won Gi photo

Chung, Won Gi
신소재공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE