Real-time in vivo monitoring of intraocular pressure distribution in the anterior chamber and vitreous chamber for diagnosis of glaucoma
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 서호철 | - |
dc.contributor.author | Hong Y.-M. | - |
dc.contributor.author | 정원기 | - |
dc.contributor.author | Park W. | - |
dc.contributor.author | Lee J. | - |
dc.contributor.author | Kim H.K. | - |
dc.contributor.author | Byeon S.H. | - |
dc.contributor.author | Kim D.W. | - |
dc.contributor.author | Park J.-U. | - |
dc.date.accessioned | 2024-10-14T07:30:16Z | - |
dc.date.available | 2024-10-14T07:30:16Z | - |
dc.date.issued | 2024-02 | - |
dc.identifier.issn | 2375-2548 | - |
dc.identifier.issn | 2375-2548 | - |
dc.identifier.uri | https://yscholarhub.yonsei.ac.kr/handle/2021.sw.yonsei/23096 | - |
dc.description.abstract | Glaucoma causes irreversible vision loss due to optic nerve damage and retinal cell degeneration. Since high intraocular pressure (IOP) is a major risk factor for glaucoma development, accurate IOP measurement is crucial, especially intravitreal IOP affecting the optical nerve and cells. However, conventional methods have limits in selectively and directly detecting local retina pressure. Here, we present continuous measurements of local IOP values in the anterior chamber and vitreous chamber of living animals using minimally invasive probes with pressure-sensitive transistors. After inducing glaucoma in animal models, we compared the local IOP distribution between normal and glaucomatous eyes. We also compared IOP values detected in the cornea using tonometry measurements. Our findings revealed that glaucoma induced higher IOP in the vitreous chamber than in the anterior chamber, indicating that measuring IOP in the vitreous chamber is key to the glaucoma model. This progress offers future directions for diagnosis and treatment of glaucoma. | - |
dc.publisher | AMER ASSOC ADVANCEMENT SCIENCE | - |
dc.title | Real-time in vivo monitoring of intraocular pressure distribution in the anterior chamber and vitreous chamber for diagnosis of glaucoma | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1126/sciadv.adk7805 | - |
dc.identifier.scopusid | 2-s2.0-85184676012 | - |
dc.identifier.wosid | 001190871400007 | - |
dc.identifier.bibliographicCitation | SCIENCE ADVANCES, v.10, no.6 | - |
dc.citation.title | SCIENCE ADVANCES | - |
dc.citation.volume | 10 | - |
dc.citation.number | 6 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.identifier.url | https://www.science.org/doi/10.1126/sciadv.adk7805 | - |
Items in Scholar Hub are protected by copyright, with all rights reserved, unless otherwise indicated.
Yonsei University 50 Yonsei-ro Seodaemun-gu, Seoul, 03722, Republic of Korea1599-1885
© 2021 YONSEI UNIV. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.