Size-classified monitoring of ATP bioluminescence for rapid assessment of biological distribution in airborne particulates
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 오재호 | - |
dc.contributor.author | Choi Jisoo | - |
dc.contributor.author | Massoudifarid Milad | - |
dc.contributor.author | Park Ja Young | - |
dc.contributor.author | Hwang Jungho | - |
dc.contributor.author | Lim Jiseok | - |
dc.contributor.author | Byeon Jeong Hoon | - |
dc.date.accessioned | 2024-11-12T23:30:14Z | - |
dc.date.available | 2024-11-12T23:30:14Z | - |
dc.date.issued | 2023-08 | - |
dc.identifier.issn | 0956-5663 | - |
dc.identifier.issn | 1873-4235 | - |
dc.identifier.uri | https://yscholarhub.yonsei.ac.kr/handle/2021.sw.yonsei/23112 | - |
dc.description.abstract | The COVID-19 pandemic ignited massive research into the rapid detection of bioaerosols. In particular, nanotechnology-based detection strategies are proposed as alternatives because of issues in bioaerosol enrichment and lead time for molecular diagnostics; however, the practical implementation of such techniques is still unclear due to obstacles regarding the large research and development effort and investment for the validation. The use of adenosine triphosphate (ATP) bioluminescence (expressed as relative luminescence unit (RLU) per unit volume of air) of airborne particulate matter (PM) to determine the bacterial population as a representative of the total bioaerosols (viruses, bacteria, and fungi) has been raised frequently because of the high reponse speed, resolution, and compatibility with culture-based bioaerosol monitoring. On the other hand, additional engineering attempts are required to confer significance because of the size-classified (bioluminescence for different PM sizes) and specific (bioluminescence per unit PM mass) biological risks of air for providing proper interventions in the case of airborne transmission. In this study, disc-type impactors to cut-off aerosols larger than 1 mu m, 2.5 mu m, and 10 mu m were designed and constructed to collect PM1, PM2.5, and PM10 on sampling swabs. This engineering enabled reliable size-classified bioluminescence signals using a commercial ATP luminometer after just 5 min of air intake. The simultaneous operations of a six-stage Andersen impactor and optical PM spectrometers were conducted to determine the correlations between the resulting RLU and colony forming unit (CFU; from the Andersen impactor) or PM mass concentration (deriving specific bioluminescence). | - |
dc.publisher | Pergamon Press Ltd. | - |
dc.title | Size-classified monitoring of ATP bioluminescence for rapid assessment of biological distribution in airborne particulates | - |
dc.type | Article | - |
dc.publisher.location | 영국 | - |
dc.identifier.doi | 10.1016/j.bios.2023.115356 | - |
dc.identifier.wosid | 001006902600001 | - |
dc.identifier.bibliographicCitation | Biosensors and Bioelectronics, v.234 | - |
dc.citation.title | Biosensors and Bioelectronics | - |
dc.citation.volume | 234 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in Scholar Hub are protected by copyright, with all rights reserved, unless otherwise indicated.
Yonsei University 50 Yonsei-ro Seodaemun-gu, Seoul, 03722, Republic of Korea1599-1885
© 2021 YONSEI UNIV. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.