Microfluidics-based condensation bioaerosol sampler for multipoint airborne virus monitoring
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yoo Seong-Jae | - |
dc.contributor.author | 오재호 | - |
dc.contributor.author | Hong Seung-Jae | - |
dc.contributor.author | Kim Min-gu | - |
dc.contributor.author | Hwang Jungho | - |
dc.contributor.author | Kim Yong-Jun | - |
dc.date.accessioned | 2024-11-12T23:30:14Z | - |
dc.date.available | 2024-11-12T23:30:14Z | - |
dc.date.issued | 2024-11 | - |
dc.identifier.issn | 0956-5663 | - |
dc.identifier.issn | 1873-4235 | - |
dc.identifier.uri | https://yscholarhub.yonsei.ac.kr/handle/2021.sw.yonsei/23113 | - |
dc.description.abstract | To facilitate rapid monitoring of airborne viruses, they must be collected with high efficiency and concentrated in a small volume of a liquid sample. In addition, the development of low-cost miniaturized samplers is essential for multipoint monitoring. Thus, in an attempt to fulfill these requirements, this study developed a microfluidic condensation bioaerosol sampler (MCBS). The developed sampler comprised two parts: a virus growth section and a virus droplet-to-liquid sample conversion section, each of which was fabricated on a chip using microfluidic technology. The condensation nucleus growth technique used in the virus growth section grew nanometer-sized airborne viruses into micro-sized droplets, making it possible to collection of viruses easier and with high efficiency. In addition, the virus droplet-to-liquid sample conversion section controlled the transport of droplets based on electrowetting technology. This enabled the collected airborne viruses to be concentrated in tens of microliters of the liquid sample. To evaluate the performance of both the sections, the virus dropletization, virus collection efficiency, and virus droplet-to-liquid sample conversion efficiency were evaluated through quantitative experiments. H1N1 and HCOV-229E viruses were used to conduct quantitative experiments on MCBS. We could obtain virus liquid samples with at 72.8- and 89.9-times higher concentration through 1:1 evaluation with a commercial sampler. Thus, the developed sampler facilitated efficient collection and concentration of airborne viruses in a compact, cost-effective manner. This is expected to facilitate rapid and accurate multipoint monitoring of viral aerosols. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | Pergamon Press Ltd. | - |
dc.title | Microfluidics-based condensation bioaerosol sampler for multipoint airborne virus monitoring | - |
dc.type | Article | - |
dc.publisher.location | 영국 | - |
dc.identifier.doi | 10.1016/j.bios.2024.116658 | - |
dc.identifier.wosid | 001296082300001 | - |
dc.identifier.bibliographicCitation | Biosensors and Bioelectronics, v.264 | - |
dc.citation.title | Biosensors and Bioelectronics | - |
dc.citation.volume | 264 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in Scholar Hub are protected by copyright, with all rights reserved, unless otherwise indicated.
Yonsei University 50 Yonsei-ro Seodaemun-gu, Seoul, 03722, Republic of Korea1599-1885
© 2021 YONSEI UNIV. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.