Multi-modal networks for real-time monitoring of intracranial acoustic field during transcranial focused ultrasound therapy
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 서민지 | - |
dc.contributor.author | Shin Minwoo | - |
dc.contributor.author | Noh Gunwoo | - |
dc.contributor.author | Yoo Seung-Schik | - |
dc.contributor.author | Yoon Kyungho | - |
dc.date.accessioned | 2025-09-23T08:34:40Z | - |
dc.date.available | 2025-09-23T08:34:40Z | - |
dc.date.issued | 2024-12 | - |
dc.identifier.issn | 0169-2607 | - |
dc.identifier.issn | 1872-7565 | - |
dc.identifier.uri | https://yscholarhub.yonsei.ac.kr/handle/2021.sw.yonsei/25692 | - |
dc.description.abstract | Background and objective: Transcranial focused ultrasound (tFUS) is an emerging non-invasive therapeutic technology that offers new brain stimulation modality. Precise localization of the acoustic focus to the desired brain target throughout the procedure is needed to ensure the safety and effectiveness of the treatment, but acoustic distortion caused by the skull poses a challenge. Although computational methods can provide the estimated location and shape of the focus, the computation has not reached sufficient speed for real-time inference, which is demanded in real-world clinical situations. Leveraging the advantages of deep learning, we propose multi-modal networks capable of generating intracranial pressure map in real-time. Methods: The dataset consisted of free-field pressure maps, intracranial pressure maps, medical images, and transducer placements was obtained from 11 human subjects. The free-field and intracranial pressure maps were computed using the k-space method. We developed network models based on convolutional neural networks and the Swin Transformer, featuring a multi-modal encoder and a decoder. Results: Evaluations on foreseen data achieved high focal volume conformity of approximately 93% for both computed tomography (CT) and magnetic resonance (MR) data. For unforeseen data, the networks achieved the focal volume conformity of 88% for CT and 82% for MR. The inference time of the proposed networks was under 0.02 s, indicating the feasibility for real-time simulation. Conclusions: The results indicate that our networks can effectively and precisely perform real-time simulation of the intracranial pressure map during tFUS applications. Our work will enhance the safety and accuracy of treatments, representing significant progress for low-intensity focused ultrasound (LIFU) therapies. | - |
dc.publisher | Elsevier BV | - |
dc.title | Multi-modal networks for real-time monitoring of intracranial acoustic field during transcranial focused ultrasound therapy | - |
dc.type | Article | - |
dc.publisher.location | 아일랜드 | - |
dc.identifier.doi | 10.1016/j.cmpb.2024.108458 | - |
dc.identifier.wosid | 001343436700001 | - |
dc.identifier.bibliographicCitation | Computer Methods and Programs in Biomedicine, v.257 | - |
dc.citation.title | Computer Methods and Programs in Biomedicine | - |
dc.citation.volume | 257 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
Items in Scholar Hub are protected by copyright, with all rights reserved, unless otherwise indicated.
Yonsei University 50 Yonsei-ro Seodaemun-gu, Seoul, 03722, Republic of Korea1599-1885
© 2021 YONSEI UNIV. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.