Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

실내 공간에서의 호흡기 감염병 공기전파감염 위험도와 공기정화장치(필터 임배디드 기계식 환기설비 및 공기청정기 등 실내 감염원 저감 장치) 사용에 따른 효율Airborne infection risk of respiratory infectious diseases and effectiveness of using filter-embeded mechanical ventilator and infectious source reduction device such as air cleaner

Other Titles
Airborne infection risk of respiratory infectious diseases and effectiveness of using filter-embeded mechanical ventilator and infectious source reduction device such as air cleaner
Authors
박성재박근영박대훈구현본황정호
Issue Date
Dec-2020
Publisher
한국입자에어로졸학회
Citation
PARTICLE AND AEROSOL RESEARCH, v.16, no.4, pp 73 - 94
Pages
22
Journal Title
PARTICLE AND AEROSOL RESEARCH
Volume
16
Number
4
Start Page
73
End Page
94
URI
https://yscholarhub.yonsei.ac.kr/handle/2021.sw.yonsei/5398
DOI
10.11629/jpaar.2020.16.4.073
ISSN
1738-8716
Abstract
Particulate infectious sources, including infectious viruses, can float in the air, causing airborne infections. To prevent indoor airborne infection, dilution control by ventilation and indoor air cleaners are frequently used. In this study, the risk of airborne infection by the operation of these two techniques was evaluated. In case of dilution control by ventilation, a high efficiency air filter was embedded at the inlet of supply air. In this study, infectious source reduction devices such as indoor air cleaner include all kinds of mechanical-filters, UV-photo catalysts and air ionizers through which air flow is forced by fans. Two mathematical models for influenza virus were applied in an infant care room where infants and young children are active, and the risk reduction efficiency was compared. As a result, in the case of individually operating the ventilator or the infectious source reduction device, the airborne infection risk reduction efficiencies were 55.2~61.2% and 53.8~59.9%, respectively. When both facilities were operated, it was found that the risk of airborne infection was reduced about 72.2~76.8%. Therefore, simultaneous operation of ventilation equipment and infectious source reduction device is the most effective method for safe environment that minimizes the risk of airborne infection of respiratory infectious diseases. In the case of a space where sufficient ventilation operation is difficult, it was found that the operation of an infectious source reduction device is important to prevent the spread of infectious diseases. This study is meaningful in that it provides an academic basis for strategies for preventing airborne infection of respiratory infectious diseases.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Mechanical Engineering > 1. Journal Articles

qrcode

Items in Scholar Hub are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Sungjae photo

Park, Sungjae
College of Engineering (Mechanical Engineering)
Read more

Altmetrics

Total Views & Downloads

BROWSE