Rapid detection of influenza A (H1N1) virus by conductive polymer-based nanoparticle via optical response to virus-specific binding
DC Field | Value | Language |
---|---|---|
dc.contributor.author | GEUNSEON PARK | - |
dc.contributor.author | Hyun-Ouk Kim | - |
dc.contributor.author | JONG-WOO LIM | - |
dc.contributor.author | CHAEWON PARK | - |
dc.contributor.author | Minjoo Yeom | - |
dc.contributor.author | Daesub Song | - |
dc.contributor.author | SEUNGJOO HAAM | - |
dc.date.accessioned | 2022-03-04T03:40:07Z | - |
dc.date.available | 2022-03-04T03:40:07Z | - |
dc.date.issued | 2022-03 | - |
dc.identifier.issn | 1998-0124 | - |
dc.identifier.uri | https://yscholarhub.yonsei.ac.kr/handle/2021.sw.yonsei/6283 | - |
dc.description.abstract | A recurrent pandemic with unpredictable viral nature has implied the need for a rapid diagnostic technology to facilitate timely and appropriate countermeasures against viral infections. In this study, conductive polymer-based nanoparticles have been developed as a tool for rapid diagnosis of influenza A (H1N1) virus. The distinctive property of a conductive polymer that transduces stimulus to respond, enabled immediate optical signal processing for the specific recognition of H1N1 virus. Conductive poly(aniline-co-pyrrole)-encapsulated polymeric vesicles, functionalized with peptides, were fabricated for the specific recognition of H1N1 virus. The low solubility of conductive polymers was successfully improved by employing vesicles consisting of amphiphilic copolymers, facilitating the viral titer-dependent production of the optical response. The optical response of the detection system to the binding event with H1N1, a mechanical stimulation, was extensively analyzed and provided concordant information on viral titers of H1N1 virus in 15 min. The specificity toward the H1N1 virus was experimentally demonstrated via a negative optical response against the control group, H3N2. Therefore, the designed system that transduces the optical response to the target-specific binding can be a rapid tool for the diagnosis of H1N1. [Figure not available: see fulltext.] | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | TSINGHUA UNIV PRESS | - |
dc.title | Rapid detection of influenza A (H1N1) virus by conductive polymer-based nanoparticle via optical response to virus-specific binding | - |
dc.type | Article | - |
dc.publisher.location | 중국 | - |
dc.identifier.doi | 10.1007/s12274-021-3772-6 | - |
dc.identifier.scopusid | 2-s2.0-85115257546 | - |
dc.identifier.bibliographicCitation | NANO RESEARCH, v.15, no.3, pp 2,254 - 2,262 | - |
dc.citation.title | NANO RESEARCH | - |
dc.citation.volume | 15 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 2,254 | - |
dc.citation.endPage | 2,262 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordAuthor | Influenza A (H1N1) virus | - |
dc.subject.keywordAuthor | Conductive polymer | - |
dc.subject.keywordAuthor | Optical property | - |
Items in Scholar Hub are protected by copyright, with all rights reserved, unless otherwise indicated.
Yonsei University 50 Yonsei-ro Seodaemun-gu, Seoul, 03722, Republic of Korea1599-1885
© 2021 YONSEI UNIV. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.