Improving phase-based conductivity reconstruction by means of deep learning-based denoising of B1+ phase data for 3T MRI
DC Field | Value | Language |
---|---|---|
dc.contributor.author | KYU JIN JUNG | - |
dc.contributor.author | Stefano Mandija | - |
dc.contributor.author | junhyeong kim | - |
dc.contributor.author | RyuKangHyun | - |
dc.contributor.author | SooZy Jung | - |
dc.contributor.author | CHUANJIANGCUI | - |
dc.contributor.author | Soo-Yeon Kim | - |
dc.contributor.author | Mina Park | - |
dc.contributor.author | Cornelis A.T. van den Berg | - |
dc.contributor.author | DONGHYUN KIM | - |
dc.date.accessioned | 2023-04-10T01:40:10Z | - |
dc.date.available | 2023-04-10T01:40:10Z | - |
dc.date.issued | 2021-10 | - |
dc.identifier.issn | 0740-3194 | - |
dc.identifier.uri | https://yscholarhub.yonsei.ac.kr/handle/2021.sw.yonsei/6345 | - |
dc.description.abstract | Purpose To denoise B1+ phase using a deep learning method for phase-based in vivo electrical conductivity reconstruction in a 3T MR system. Methods For B1+ phase deep-learning denoising, a convolutional neural network (U-net) was chosen. Training was performed on data sets from 10 healthy volunteers. Input data were the real and imaginary components of single averaged spin-echo data (SNR = 45), which was used to approximate the B1+ phase. For label data, multiple signal-averaged spin-echo data (SNR = 128) were used. Testing was performed on in silico and in vivo data. Reconstructed conductivity maps were derived using phase-based conductivity reconstructions. Additionally, we investigated the usability of the network to various SNR levels, imaging contrasts, and anatomical sites (ie, T1, T2, and proton density?weighted brain images and proton density?weighted breast images. In addition, conductivity reconstructions from deep learning?based denoised data were compared with conventional image filters, which were used for data denoising in electrical properties tomography (ie, the Gaussian filtering and the Savitzky-Golay filtering). Results The proposed deep learning?based denoising approach showed improvement for B1+ phase for both in silico and in vivo experiments with reduced quantitative error measures compared with other methods. Subsequently, this resulted in an improvement of reconstructed conductivity maps from the denoised B1+ phase with deep learning. Conclusion The results suggest that the proposed approach can be used as an alternative preprocessing method to denoise B1+ maps for phase-based conductivity reconstruction without relying on image filters or signal averaging. | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | WILEY-BLACKWELL | - |
dc.title | Improving phase-based conductivity reconstruction by means of deep learning-based denoising of B1+ phase data for 3T MRI | - |
dc.type | Article | - |
dc.publisher.location | 미국 | - |
dc.identifier.doi | 10.1002/mrm.28826 | - |
dc.identifier.scopusid | 2-s2.0-85105662941 | - |
dc.identifier.bibliographicCitation | MAGNETIC RESONANCE IN MEDICINE, v.86, no.4, pp 2,084 - 2,094 | - |
dc.citation.title | MAGNETIC RESONANCE IN MEDICINE | - |
dc.citation.volume | 86 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 2,084 | - |
dc.citation.endPage | 2,094 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordAuthor | B1+ Phase | - |
dc.subject.keywordAuthor | deep learning | - |
dc.subject.keywordAuthor | denoising | - |
dc.subject.keywordAuthor | electrical properties tomography | - |
dc.subject.keywordAuthor | phase-based conductivity reconstruction | - |
Items in Scholar Hub are protected by copyright, with all rights reserved, unless otherwise indicated.
Yonsei University 50 Yonsei-ro Seodaemun-gu, Seoul, 03722, Republic of Korea1599-1885
© 2021 YONSEI UNIV. ALL RIGHTS RESERVED.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.