Detailed Information

Cited 3 time in webofscience Cited 0 time in scopus
Metadata Downloads

Strain-Insensitive Stretchable Fiber Conductors Based on Highly Conductive Buckled Shells for Wearable Electronics

Full metadata record
DC Field Value Language
dc.contributor.authorYoon Kukro-
dc.contributor.authorLee Sanghyeon-
dc.contributor.authorShim Donghun-
dc.contributor.authorLee Minkyu-
dc.contributor.authorCho Sungjoon-
dc.contributor.authorKwon Chaebeen-
dc.contributor.authorWon, Chihyeong-
dc.contributor.authorLee Jinhan-
dc.contributor.authorJung Han Hee-
dc.contributor.authorLee Seungmin-
dc.contributor.authorJang Kyung-In-
dc.contributor.authorLee Jaehong-
dc.contributor.authorLee Taeyoon-
dc.date.accessioned2023-05-22T00:40:03Z-
dc.date.available2023-05-22T00:40:03Z-
dc.date.issued2023-04-
dc.identifier.issn1944-8244-
dc.identifier.issn1944-8252-
dc.identifier.urihttps://yscholarhub.yonsei.ac.kr/handle/2021.sw.yonsei/6662-
dc.description.abstractBased on their high applicability to wearable electronics, fiber-based stretchable electronics have been developed via different strategies. However, the electrical conductivity of a fiber electrode is severely degraded, following deformation upon stretching. Despite the introduction of conductive buckled structures to resolve this issue, there still exist limitations regarding the simultaneous realizations of high conductivity and stretchability. Here, we exploit the dense distribution of the Ag nanoparticle (AgNP) network in polyurethane (PU) to fabricate a strain-insensitive stretchable fiber conductor comprising highly conductive buckled shells via a facile chemical process. These buckled AgNPs/PU fibers exhibit stable and reliable electrical responses across a wide range (tensile strain = similar to 200%), in addition to their high electrical conductivity (26,128 S/m) and quality factor (Q = 2.29). Particularly, the negligible electrical hysteresis and excellent durability (>10,000 stretching-releasing cycles) of the fibers demonstrate their high applicability to wearable electronics. Furthermore, we develop buckled fiber-based pH sensors exhibiting stable, repeatable, and highly distinguishable responses (changing pH is from 4 to 8, response time is 5-6 s) even under 100% tensile strain. The buckled AgNPs/ PU fibers represent a facile strategy for maintaining the stable electrical performances of fiber electrodes across the strain range of human motion for wearable-
dc.format.extent9-
dc.language영어-
dc.language.isoENG-
dc.publisherAmerican Chemical Society-
dc.titleStrain-Insensitive Stretchable Fiber Conductors Based on Highly Conductive Buckled Shells for Wearable Electronics-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.wosid000962876900001-
dc.identifier.bibliographicCitationACS Applied Materials & Interfaces, v.15, no.14, pp 18281 - 18289-
dc.citation.titleACS Applied Materials & Interfaces-
dc.citation.volume15-
dc.citation.number14-
dc.citation.startPage18281-
dc.citation.endPage18289-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > 공과대학 전기전자공학부 > 공과대학 전기전자공학과 > 1. Journal Articles

qrcode

Items in Scholar Hub are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Won, Chihyeong photo

Won, Chihyeong
공과대학 전기전자공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE