Detailed Information

Cited 0 time in webofscience Cited 2 time in scopus
Metadata Downloads

다중 2D 레이저 스캐너 시스템의 외부 표정요소 캘리브레이션을 위한 시뮬레이션 기반 표적 배치 결정 기법Simulation based Target Geometry Determination Method for Extrinsic Calibration of Multiple 2D Laser Scanning Syste

Other Titles
Simulation based Target Geometry Determination Method for Extrinsic Calibration of Multiple 2D Laser Scanning Syste
Authors
SUNGHA JUSanghyun YOONsangyoon parkJOON HEO
Issue Date
Dec-2018
Publisher
Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
Keywords
외부 표정요소 검정; 2D 레이저 스캐닝 시스템; 검정 설계; 시뮬레이션; 2D laser scanning system; Calibration design; Extrinsic calibration; Simulation
Citation
Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography, v.36, no.6, pp 443 - 449
Pages
7
Journal Title
Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
Volume
36
Number
6
Start Page
443
End Page
449
URI
https://yscholarhub.yonsei.ac.kr/handle/2021.sw.yonsei/6722
DOI
10.7848/ksgpc.2018.36.6.443
ISSN
1598-4850
Abstract
SLAM (Simultaneous Localization and Mapping) 기반 모바일 매핑 시스템을 활용한 실내 공간의 포인트 클라 우드 취득은 건축물의 유지, 관리를 위한 as-built BIM (Building Information Model) 구축의 기초 공정이다. 본 연 구에서는 다중 2D 레이저 스캐너로 구성된 모바일 매핑 시스템의 구축을 위한 시뮬레이션 기반 검정(calibration) 표적의 구조 결정 방법을 제안하다. 2D 레이저 스캐너의 외부 표정요소 검정을 위해 (1) 원형, (2) 사각형, (3) 이중 원형, (4) 이중 사각형 형태의 표적을 구성하다. 시뮬레이션을 통해 얻어진 각 표적 관측 값을 토대로, 최소제곱법 기반의 외부 표정요소 검정을 수행하다. 그 결과 사각형 형태의 표적 구조가 주어진 시스템의 검정에 가장 적합 한 형태임을 확인하다. 또한 외부 표정요소 간의 높은 상관성을 확인할 수 있었으며, 표적의 구조에 따른 외부 표 정요소의 검정 결과가 상이한 것으로 나타났다. Acquiring indoor point cloud, using SLAM (Simultaneous Localization and Mapping) based mobile mapping system, is an element progress for development of as-build BIM (Building Information Model) for the maintenance of the building. In this research we proposed a simulation-based target geometry determination for extrinsic calibration of multiple 2D laser scanning mobile system. Four different types of calibration sites were designed: (1) circle type; (2) rectangle type; (3) double circle type; and (4) double rectangle type. Based on the measurement values obtained from each simulated calibration site geometry, least squares solution based extrinsic calibration was derived. As a result, the rectangle type geometry is most suitable for extrinsic calibration of this system. Also, correlation values between extrinsic calibration parameters were high, and calibration results were distinct according to the calibration sites. © 2018 Korean Society of Surveying. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > 공과대학 사회환경시스템공학부 > 공과대학 건설환경공학과 > 1. Journal Articles

qrcode

Items in Scholar Hub are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Sangyoon photo

Park, Sangyoon
공과대학 건설환경공학
Read more