Detailed Information

Cited 6 time in webofscience Cited 8 time in scopus
Metadata Downloads

Electrosprayed Thylakoid–Alginate Film on a Micro-Pillar Electrode for Scalable Photosynthetic Energy Harvesting

Authors
SEONILKIMYONGJAE KimHYEONAUG HONGJAEHYOUNG YunWonHyoung Ryu
Issue Date
Dec-2020
Publisher
AMER CHEMICAL SOC
Keywords
photosynthesis; energy harvesting; electrospraying; thylakoids-alginate film; SU-8 micropillar electrode
Citation
ACS APPLIED MATERIALS & INTERFACES, v.12, no.49, pp 54,683 - 54,693
Journal Title
ACS APPLIED MATERIALS & INTERFACES
Volume
12
Number
49
Start Page
54,683
End Page
54,693
URI
https://yscholarhub.yonsei.ac.kr/handle/2021.sw.yonsei/23140
DOI
10.1021/acsami.0c15993
ISSN
1944-8244
Abstract
Direct harvesting of electricity from photosynthesis is highly desired as an eco-friendly and sustainable energy harvesting technology. Photosynthetic apparatuses isolated from plants, such as thylakoid membranes (TMs), are deposited on an electrode by which photosynthetic electrons (PEs) are collected from water splitting. To enhance PE collection efficiency, it is critical to increase the electrochemical interfaces between TMs and the electrode. Considering the size of TMs to be around a few hundred nanometer, we hypothesize that an array of micropillar-shaped (MP) electrode can maximize the TM/electrode interface area. Thus, we developed MP electrodes with different heights and investigated the electrospraying of TM-alginate mixtures to fill the gaps between MPs uniformly and conformally. The uniformity of the TM-alginate film and the interaction between the TM and the MP electrode were evaluated to understand how the MP heights and film quality influenced the magnitude of the PE currents. PE currents increased up to 2.4 times for an MP electrode with an A/R of 1.8 compared to a flat electrode, indicating increased direct contact interface between TMs and the electrode. Furthermore, to demonstrate the scalability of this approach, an array of replicated SU-8 MP electrodes was prepared and PE currents of up to 3.2 mu A were monitored without a mediator under 68 mW/cm(2). Finally, the PE current harvesting was sustained for 14 days without decay, demonstrating the long-term stability of the TM-alginate biophotoanodes.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > 공과대학 기계공학부 > 공과대학 기계공학과 > 1. Journal Articles

qrcode

Items in Scholar Hub are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher ,  photo

,
기계공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE