Building retrofit technology strategy and effectiveness evaluation for reducing energy use by indoor air quality control

Authors
조호현남지희최지용SUNGWOONG YANGYUJIN KANGSUMIN KIM
Issue Date
May-2022
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Indoor air quality; Educational building; Airtightness; Retrofit; Net present value
Citation
BUILDING AND ENVIRONMENT, v.216, pp 108984-1 - 108984-16
Journal Title
BUILDING AND ENVIRONMENT
Volume
216
Start Page
108984-1
End Page
108984-16
URI
https://yscholarhub.yonsei.ac.kr/handle/2021.sw.yonsei/6698
DOI
10.1016/j.buildenv.2022.108984
ISSN
0360-1323
1873-684X
Abstract
Ultra-fine dust refers to particulate matter from external sources, and modernization contributes toward increasing the presence of ultra-fine dust. Young children are particularly vulnerable to the ill effects of ultra-fine dust. Educational buildings, where young children spend the longest duration after their houses, are typically difficult to retrofit. Consequently, they are often used for a long time in the same state as they were when first completed. The buildings deteriorate due to long-term use, particularly because the openings are opened and closed frequently by occupants. Hence, architectural retrofits were performed during vacation, and the effects were evaluated. The evaluation factors include the temperature, relative humidity, and presence of ultra-fine dust. It was confirmed that the temperature and humidity inside the room decreased after the retrofit, while the airtightness performance was strengthened, thereby reducing the I/O ratio. To evaluate the sustainability of architectural remodeling with regard to not only the indoor air environment but also the enhancement of airtightness and insulation performance through the retrofit, a representative scenario was selected with reference to the Intergovernmental Panel on Climate Change's Future Climate Report. Although it was found that improving both the main entrance and the outdoor window was appropriate, replacing only the outdoor window was the adjudged the optimal retrofit scenario in consideration of the recovery of the investment cost.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > 공과대학 건축·도시공학부 > 공과대학 건축공학과 > 1. Journal Articles

qrcode

Items in Scholar Hub are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher ,  photo

,
공과대학 건축공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE